Site Navigation

(VG031) 35mL Absorption Cuvette with Lid, Glass Material, Fused, Lightpath 100mm, 350 – 2000nm, 2 Clear Walls

Weight 200 g
Brand

Resistant to Chemicals

SKU: VG031

$62.00

In Stock

This glass absorption cuvette is for spectrophotometry applications, with a path length of 100 mm. Resistant to most chemicals. Use upto 600°C.  The price is for 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist
Compare
  • Type: Fused
Worldwide Timed Dispatch Available
  • Free Shipping apply to all orders over $800
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Fast dispatch. Receive deliveries in 2 - 3 weeks.

Description

VG031 – 35 mL Glass Absorption Cuvette (Fused, 100 mm Path Length, 2 Windows, With Lid)

The VG031 is a long-path optical glass cuvette designed for absorption spectroscopy in the visible and near-infrared regions.
With a 100 mm optical path length, it significantly increases sensitivity and enables detection of low-concentration analytes.
Its fused construction ensures mechanical stability, long service life, and reliable optical alignment for precision measurements.

Key Features

  • Sample volume: 35 mL — suitable for long-path, high-sensitivity measurements.
  • 100 mm optical path length: ideal for trace analysis and extended absorbance measurements.
  • 2 optical windows: high-quality polish for low scattering and high transmission.
  • Optical glass material: excellent performance in the visible to NIR range (350–2000 nm).
  • Fused fabrication: provides stability and good chemical resistance for repeated use.
  • Wavelength range: VIS (350 – 2000 nm).

Typical Applications

  • Trace and ultra-trace concentration measurements
  • Environmental monitoring (e.g., nitrates, phosphates)
  • Colorimetric analysis requiring extended path lengths
  • Routine laboratory and QA/QC spectroscopy

Cuvette Specifications

Type 100 mm Glass Cuvette Optical Path Length 100 mm
Article No. VG031 Volume 35,000 µL
Measuring Method Absorption Cells Material Optical Glass
Number of Windows 2 Wavelength Range VIS (350 – 2000 nm)
Outside Dimensions
Height 45 mm Width 12.5 mm
Depth 102.5 mm
Inside Dimensions
Width 10 mm Depth (Inside) 100 mm
Center Height (Z) 8.5 – 20 mm Fabrication Method Fused*
Package Cell & Lid

About Long-Path Glass Cuvettes

Long-path glass cuvettes are highly effective for boosting detection sensitivity in VIS/NIR spectroscopy:

  • Excellent transmission between 350–2000 nm.
  • Ideal for measuring dilute solutions or weak absorbance signals.
  • Durable fused glass construction ensures long-term stability.
  • Not suitable for UV measurements below 350 nm.

Usage Notes

  • Designed for trace-level absorbance measurements requiring longer optical paths.
  • Compatible with standard spectrophotometers equipped for long-path cuvettes.
  • Not recommended for use with strong acids, alkalis, or aggressive organic solvents.

Note: For UV applications or use with harsh chemicals, quartz cuvettes are recommended. Glass cuvettes are ideal for visible/NIR trace analysis.

1

Cuvette Specifications

1234
Type100mm Glass CuvetteOptical Path Length100 mm
Article No.VG031Volume35000 µl
Measuring MethodAbsorption CellsMaterialOptical Glass
Number of Windows2Wavelength RangeVIS (350 - 2000 nm)
Outside DimensionsInside Dimensions
Height45 mmWidth10 mm
Width12.5 mmDepth100 mm
Depth102.5 mmCenter Height (Z)8.5 - 20 mm
Fabrication MethodFused*PackageCell & Lid
1

Comparison of Fabrication Types

1234
*Molded*Fused*Bonded
Visible ( 350 - 2000 nm)YesYesYes
Transmission Matched On RequestNoNo
Transmission > 80%YesYesYes
Resistant to Acids and Bases (except hydrofluoric acid)YesYesNo
Resistant to Organic SolventsYesYesNo
Usable upto 600°C (1112°F)YesYesYes
Usable upto 1200°C (2192°F)YesNoNo
0 Variations ReadingOn RequestNoNo
FabricationMoldedAssembled with Glass PowderAssembled with Glue
AdhesivesNoNoYes
StorageShort Term StorageClean After UseClean After Use
Available MaterialOptical Glass Material
NoteMolded and fused cuvettes and cells are assembled by direct fusion without the use of adhesives throughout the production process. This guarantees resistance against corrosive chemicals and high temperature. Each glass cuvette and cell has excellent transmission from 350nm to 2000nm under visible light range.

 

1

To the best of our knowledge, the technical information provided here is accurate. However, Qvarz.com assumes no liability for the accuracy of this information. The values provided here are typical at the time of manufacture and may vary over time and from batch to batch.

Additional information

Weight 200 g
Brand

Resistant to Chemicals

Reviews

There are no reviews yet.

Be the first to review “(VG031) 35mL Absorption Cuvette with Lid, Glass Material, Fused, Lightpath 100mm, 350 – 2000nm, 2 Clear Walls”