(VLB16M) Cellule de cytométrie en flux 16 μL, trajet optique 0,2 mm, comptage de cellules, 2 fenêtres, collées
$217.00
Cette cuvette à circulation est destinée aux applications de cytométrie en flux, avec un trajet optique de 0,2 mm. Pour les échantillons aqueux uniquement. Utilisation jusqu’à 100°C. Le prix est pour 1 pièce .
Description
Spécifications de la Flow Cell
1 | 2 | 3 | 4 | |||
---|---|---|---|---|---|---|
Type | Flow Cell | Optical Path Length | 0.2 mm | |||
Article No. | VLB16M | Application | Cell Counting, Flow Cytometry | |||
Measuring Method | Absorption Cells | Volume | 16μL | |||
Number of Windows | 2 | Wavelength Range | UV/VIS (190 - 2500 nm) | |||
Outside Dimensions | ||||||
Length | 30 mm | Width | 15 mm | |||
Depth | 4 mm | Fabrication Method | Bonded* |
Comparaison des types de fabrication
1 | 2 | 3 | 4 | ||
---|---|---|---|---|---|
*Molded | *Fused | *Bonded / Glued | |||
UV vis ( 190- 2500 nm) | Yes | Yes | Yes | ||
Transmission Matched | On Request | No | No | ||
Transmission > 80% | Yes | Yes | Yes | ||
Resistant to Acids and Bases (except hydrofluoric acid) | Yes | Yes | No | ||
Resistant to Organic Solvents | Yes | Yes | No | ||
Usable upto 600°C (1112°F) | Yes | Yes | Yes | ||
Usable upto 1200°C (2192°F) | Yes | No | No | ||
0 Variations Reading | On Request | No | No | ||
Fabrication | Molded | Assembled with Quartz Powder | Assembled with Glue | ||
Adhesives | No | No | Yes | ||
Storage | Short Term Storage | Clean After Use | Clean After Use | ||
Available Material | Fused Quartz Material | ||||
Note | Molded and fused cuvettes and cells are assembled by direct fusion without the use of adhesives throughout the production process. This guarantees resistance against corrosive chemicals and high temperature. Each quartz cuvette and cell has excellent transmission from 190nm to 2500nm. |
You must be logged in to post a review.
(VLB16M) Κυψέλη κυτταρομετρίας ροής 16μL, Διαδρομή φωτός 0,2 χιλιοστά, Καταμέτρηση κυττάρων, 2 παράθυρα, συνδεδεμένο
$217.00
Αυτή η κυψελίδα ροής προορίζεται για εφαρμογές κυτταρομετρίας ροής, με μήκος διαδρομής 0,2 mm. Μόνο για υδατικά δείγματα. Χρήση έως 100°C. Η τιμή είναι για 1 τεμάχιο .
Description
Προδιαγραφές κυψελών ροής
1 | 2 | 3 | 4 | |||
---|---|---|---|---|---|---|
Type | Flow Cell | Optical Path Length | 0.2 mm | |||
Article No. | VLB16M | Application | Cell Counting, Flow Cytometry | |||
Measuring Method | Absorption Cells | Volume | 16μL | |||
Number of Windows | 2 | Wavelength Range | UV/VIS (190 - 2500 nm) | |||
Outside Dimensions | ||||||
Length | 30 mm | Width | 15 mm | |||
Depth | 4 mm | Fabrication Method | Bonded* |
Σύγκριση τύπων κατασκευής
1 | 2 | 3 | 4 | ||
---|---|---|---|---|---|
*Molded | *Fused | *Bonded / Glued | |||
UV vis ( 190- 2500 nm) | Yes | Yes | Yes | ||
Transmission Matched | On Request | No | No | ||
Transmission > 80% | Yes | Yes | Yes | ||
Resistant to Acids and Bases (except hydrofluoric acid) | Yes | Yes | No | ||
Resistant to Organic Solvents | Yes | Yes | No | ||
Usable upto 600°C (1112°F) | Yes | Yes | Yes | ||
Usable upto 1200°C (2192°F) | Yes | No | No | ||
0 Variations Reading | On Request | No | No | ||
Fabrication | Molded | Assembled with Quartz Powder | Assembled with Glue | ||
Adhesives | No | No | Yes | ||
Storage | Short Term Storage | Clean After Use | Clean After Use | ||
Available Material | Fused Quartz Material | ||||
Note | Molded and fused cuvettes and cells are assembled by direct fusion without the use of adhesives throughout the production process. This guarantees resistance against corrosive chemicals and high temperature. Each quartz cuvette and cell has excellent transmission from 190nm to 2500nm. |
Reviews
There are no reviews yet.
You must be logged in to post a review.
(VLB16M) 16μL flowcytometriecel, lichtpad 0,2 mm, celtelling, 2 vensters, gebonden
$217.00
Deze doorstroomkuvet is voor flowcytometrie toepassingen, met een weglengte van 0,2 mm. Alleen voor waterige monsters. Gebruik tot 100°C. De prijs is voor 1 stuk .
Description
Specificaties stroomcel
1 | 2 | 3 | 4 | |||
---|---|---|---|---|---|---|
Type | Flow Cell | Optical Path Length | 0.2 mm | |||
Article No. | VLB16M | Application | Cell Counting, Flow Cytometry | |||
Measuring Method | Absorption Cells | Volume | 16μL | |||
Number of Windows | 2 | Wavelength Range | UV/VIS (190 - 2500 nm) | |||
Outside Dimensions | ||||||
Length | 30 mm | Width | 15 mm | |||
Depth | 4 mm | Fabrication Method | Bonded* |
Vergelijking van fabricagetypes
1 | 2 | 3 | 4 | ||
---|---|---|---|---|---|
*Molded | *Fused | *Bonded / Glued | |||
UV vis ( 190- 2500 nm) | Yes | Yes | Yes | ||
Transmission Matched | On Request | No | No | ||
Transmission > 80% | Yes | Yes | Yes | ||
Resistant to Acids and Bases (except hydrofluoric acid) | Yes | Yes | No | ||
Resistant to Organic Solvents | Yes | Yes | No | ||
Usable upto 600°C (1112°F) | Yes | Yes | Yes | ||
Usable upto 1200°C (2192°F) | Yes | No | No | ||
0 Variations Reading | On Request | No | No | ||
Fabrication | Molded | Assembled with Quartz Powder | Assembled with Glue | ||
Adhesives | No | No | Yes | ||
Storage | Short Term Storage | Clean After Use | Clean After Use | ||
Available Material | Fused Quartz Material | ||||
Note | Molded and fused cuvettes and cells are assembled by direct fusion without the use of adhesives throughout the production process. This guarantees resistance against corrosive chemicals and high temperature. Each quartz cuvette and cell has excellent transmission from 190nm to 2500nm. |
Reviews
There are no reviews yet.
You must be logged in to post a review.
Reviews
There are no reviews yet.