{"id":68831,"date":"2022-02-21T12:10:24","date_gmt":"2022-02-21T04:10:24","guid":{"rendered":"https:\/\/qvarz.com\/verification-des-spectrophotometres\/"},"modified":"2022-02-21T12:10:46","modified_gmt":"2022-02-21T04:10:46","slug":"verification-des-spectrophotometres","status":"publish","type":"post","link":"https:\/\/qvarz.com\/fr\/verification-des-spectrophotometres\/","title":{"rendered":"V\u00e9rification des spectrophotom\u00e8tres"},"content":{"rendered":"\n<p>De nombreux laboratoires sont soumis \u00e0 des exigences r\u00e9glementaires qui, par exemple, sont prescrites par les syst\u00e8mes de gestion de la qualit\u00e9. Ces laboratoires sont donc tenus de tester r\u00e9guli\u00e8rement les \u00e9quipements de travail et les instruments d&#8217;analyse, y compris les (spectro-)photom\u00e8tres. Que se passe-t-il si ces r\u00e9glementations ne s&#8217;appliquent pas \u00e0 votre laboratoire\u00a0? Dans ce cas, le test n&#8217;est pas absolument n\u00e9cessaire, car il n&#8217;est pas obligatoire &#8211; mais cela signifie-t-il qu&#8217;il n&#8217;est pas important ?<\/p>\n\n<p>N&#8217;importe qui vous dira que, s&#8217;ils avaient le choix, ils pr\u00e9f\u00e9reraient \u00e9viter des efforts, du temps et des co\u00fbts inutiles lorsqu&#8217;il s&#8217;agit d&#8217;exp\u00e9riences en laboratoire. Seule une ex\u00e9cution fluide et sans erreur de l&#8217;ensemble de l&#8217;exp\u00e9rience, du d\u00e9but \u00e0 la fin, garantira des r\u00e9sultats pr\u00e9cis et reproductibles. Ce processus comprend l&#8217;analyse, car la qualit\u00e9 des donn\u00e9es obtenues pour tout \u00e9chantillon d\u00e9pend directement de la qualit\u00e9 de la mesure elle-m\u00eame. <br\/><br\/>Par rapport \u00e0 une application de laboratoire standard telle que, par exemple, la quantification photom\u00e9trique d&#8217;acides nucl\u00e9iques, ce principe impliquerait qu&#8217;en plus de la proc\u00e9dure de purification, le processus de mesure photom\u00e9trique doit \u00eatre contest\u00e9 et test\u00e9 r\u00e9guli\u00e8rement. Des erreurs peuvent r\u00e9sulter d&#8217;une manipulation incorrecte ou la cause peut \u00eatre de nature technique. En utilisant une approche de d\u00e9pannage appropri\u00e9e avec une analyse d&#8217;erreur &#8220;\u00e9tape par \u00e9tape&#8221;, les erreurs d&#8217;application sont d\u00e9tect\u00e9es avec une relative facilit\u00e9 [1, 2]. En revanche, de nombreuses erreurs technologiques ne peuvent \u00eatre d\u00e9couvertes qu&#8217;\u00e0 l&#8217;aide de mesures comparatives et de mat\u00e9riaux de r\u00e9f\u00e9rence [3, 4].<br\/><br\/>Comment les erreurs technologiques surviennent-elles ? L&#8217;utilisation prolong\u00e9e de photom\u00e8tres peut entra\u00eener des signes d&#8217;usure dus \u00e0 des contraintes m\u00e9caniques. De plus, diff\u00e9rents facteurs environnementaux (par ex. temp\u00e9rature, humidit\u00e9, poussi\u00e8re) peuvent avoir un impact sur les performances. Ensuite, il y a toujours un risque de d\u00e9t\u00e9rioration ou de contamination par l&#8217;utilisation ou le transport. La photom\u00e9trie \u00e9tant une technologie de mesure sensible, des r\u00e9sultats erron\u00e9s peuvent donc en r\u00e9sulter. Afin d&#8217;identifier de mani\u00e8re fiable les erreurs de cette nature, il est crucial que les photom\u00e8tres soient test\u00e9s r\u00e9guli\u00e8rement. <br\/><br\/>La v\u00e9rification des dommages visibles et de la salet\u00e9, en particulier \u00e0 l&#8217;int\u00e9rieur du puits de la cuvette, constitue la premi\u00e8re \u00e9tape. Si l&#8217;instrument est \u00e9quip\u00e9 d&#8217;une fonction d&#8217;autotest int\u00e9gr\u00e9e, certaines fonctions de base peuvent \u00e9galement \u00eatre test\u00e9es \u00e0 intervalles r\u00e9guliers ou selon les besoins (figure 1a). <br\/><br\/>Afin d&#8217;obtenir des informations d\u00e9taill\u00e9es sur l&#8217;exactitude et la pr\u00e9cision des valeurs mesur\u00e9es, un test photom\u00e9trique du (spectro-)photom\u00e8tre est essentiel. Pour cela, des mesures sont r\u00e9alis\u00e9es \u00e0 l&#8217;aide de mat\u00e9riaux de r\u00e9f\u00e9rence certifi\u00e9s et tra\u00e7ables (figure 1b). Ceux-ci comprennent g\u00e9n\u00e9ralement des ensembles de filtres aux propri\u00e9t\u00e9s d\u00e9finies capables d&#8217;\u00e9tablir les longueurs d&#8217;onde et la pr\u00e9cision photom\u00e9trique d&#8217;un instrument. Les valeurs obtenues en appliquant les filtres sont ensuite compar\u00e9es aux valeurs nominales des normes de r\u00e9f\u00e9rence, et cette comparaison permet \u00e0 l&#8217;utilisateur de d\u00e9terminer si l&#8217;instrument fonctionne dans les sp\u00e9cifications techniques. Il convient de noter que les mat\u00e9riaux de r\u00e9f\u00e9rence eux-m\u00eames doivent \u00eatre test\u00e9s et certifi\u00e9s r\u00e9guli\u00e8rement. <br\/><br\/>L&#8217;inspection approfondie d&#8217;un photom\u00e8tre ne peut \u00eatre effectu\u00e9e que par une entreprise de service qualifi\u00e9e. Ce service comprend les ajustements, les r\u00e9parations et la certification si n\u00e9cessaire.<\/p>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/qvarz.com\/wp-content\/uploads\/2021\/10\/Two-methods-for-inspecting-an-Eppendorf-BioSpectrometer.jpg\"><img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"287\" src=\"https:\/\/qvarz.com\/wp-content\/uploads\/2021\/10\/Two-methods-for-inspecting-an-Eppendorf-BioSpectrometer.jpg\" alt=\"\" class=\"wp-image-55980\" title=\"\" srcset=\"https:\/\/qvarz.com\/wp-content\/uploads\/2021\/10\/Two-methods-for-inspecting-an-Eppendorf-BioSpectrometer.jpg 768w, https:\/\/qvarz.com\/wp-content\/uploads\/2021\/10\/Two-methods-for-inspecting-an-Eppendorf-BioSpectrometer-90x34.jpg 90w, https:\/\/qvarz.com\/wp-content\/uploads\/2021\/10\/Two-methods-for-inspecting-an-Eppendorf-BioSpectrometer-600x224.jpg 600w, https:\/\/qvarz.com\/wp-content\/uploads\/2021\/10\/Two-methods-for-inspecting-an-Eppendorf-BioSpectrometer-64x24.jpg 64w, https:\/\/qvarz.com\/wp-content\/uploads\/2021\/10\/Two-methods-for-inspecting-an-Eppendorf-BioSpectrometer-300x112.jpg 300w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/a><figcaption><\/figcaption><\/figure>\n<p>Figure 1 : Deux m\u00e9thodes pour inspecter un Eppendorf BioSpectrometer\u00ae<br\/>a) R\u00e9sultat d&#8217;un auto-test de l&#8217;instrument Eppendorf BioSpectrometer kinetic<br\/>b) R\u00e9sultat du test de pr\u00e9cision photom\u00e9trique d&#8217;un Eppendorf BioSpectrometer utilisant le jeu de filtres de r\u00e9f\u00e9rence associ\u00e9<\/p>\n\n<p>Une surveillance r\u00e9guli\u00e8re des photom\u00e8tres peut garantir que leurs sp\u00e9cifications continuent d&#8217;\u00eatre respect\u00e9es, m\u00eame apr\u00e8s une longue utilisation. Des m\u00e9thodes de v\u00e9rification appropri\u00e9es d\u00e9tecteront et \u00e9limineront les sources d&#8217;erreur, pr\u00e9servant ainsi la qualit\u00e9 des r\u00e9sultats d&#8217;analyse.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>De nombreux laboratoires sont soumis \u00e0 des exigences r\u00e9glementaires qui, par exemple, sont prescrites par les syst\u00e8mes de gestion de la qualit\u00e9. Ces laboratoires sont donc tenus de tester r\u00e9guli\u00e8rement les \u00e9quipements de travail et les instruments d&#8217;analyse, y compris les (spectro-)photom\u00e8tres. Que se passe-t-il si ces r\u00e9glementations ne s&#8217;appliquent pas \u00e0 votre laboratoire\u00a0? Dans<\/p>\n<div class=\"klb-readmore entry-button\"><a class=\"button\" href=\"https:\/\/qvarz.com\/fr\/verification-des-spectrophotometres\/\">Read More<\/a><\/div>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","ub_ctt_via":"","footnotes":""},"categories":[828,812],"tags":[],"class_list":["post-68831","post","type-post","status-publish","format-standard","hentry","category-spectrophotometrie","category-tous-les-messages"],"featured_image_src":null,"author_info":{"display_name":"admin","author_link":"https:\/\/qvarz.com\/fr\/author\/admin\/"},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"bacola-woo-product":false,"woocommerce_thumbnail":false,"woocommerce_single":false,"woocommerce_gallery_thumbnail":false,"variation_swatches_image_size":false,"variation_swatches_tooltip_size":false,"dgwt-wcas-product-suggestion":false},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/qvarz.com\/fr\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"De nombreux laboratoires sont soumis \u00e0 des exigences r\u00e9glementaires qui, par exemple, sont prescrites par les syst\u00e8mes de gestion de la qualit\u00e9. Ces laboratoires sont donc tenus de tester r\u00e9guli\u00e8rement les \u00e9quipements de travail et les instruments d&#8217;analyse, y compris les (spectro-)photom\u00e8tres. Que se passe-t-il si ces r\u00e9glementations ne s&#8217;appliquent pas \u00e0 votre laboratoire\u00a0? DansRead\u2026","_links":{"self":[{"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/posts\/68831","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/comments?post=68831"}],"version-history":[{"count":1,"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/posts\/68831\/revisions"}],"predecessor-version":[{"id":68834,"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/posts\/68831\/revisions\/68834"}],"wp:attachment":[{"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/media?parent=68831"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/categories?post=68831"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qvarz.com\/fr\/wp-json\/wp\/v2\/tags?post=68831"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}